CEREBRAL ANGIOGRAM

PREOP:

  • Check coags
  • Neuro exam
  • Room 5 - biplane
  • Will give heparin as soon as access obtained unless contraindicated

 

Equipment Always Necessary

  • 19G needle
  • J-wire
  • 6Fr Pigtail
  • Vertebral angle catheter (5Fr-100cm)
  • Wire: Glidewire

 

 

PREP:

  • POSITION: Supine
  • Head holder - tape the head and instruct the patient to be still. 
  • DRAPE: standard
  • LOAD THE INJECTOR - 100cc
  • Make sure Spin working before prepping the patient
  • Bring both AP and lateral in position before starting 
  • Make sure the Leonardo is turned on !!!

Stand by Equipment

  • 6Fr Sim 2 catheter
  • IM catheter
Screen Shot 2013-12-28 at 3.05.44 PM.png


Screen Shot 2013-12-28 at 3.09.11 PM.png

Dressing:

  • No dressing, just Dermabond.

PEARLS:

  • Make sure machine is able to move to locations necessary to obtain the image.
  • The complete study is a 4-vessel cerebral angiogram which includes bilateral carotids and bilateral verts. If injection in one vert opacifie the contralateral PICA it is considered a complete study. 
  • A 6-vessel cerebral angiogram includes the external carotid.